Model:
VMX-Agility
Start Soft Starters VMX-Agility
Start Soft Starters VMX-Agility, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.
Features
i23 smart application pre-program suite
A suite of pre‑programmed application ‘complete setup’ profiles facilitate a quick and comprehensive commission process to give freedom and independence to engineers. Typical VMX-agility™ setup takes less than 1 minute whereas a comparable competitive product commission could be 60 to 120 minutes for only a partial setup. Access to an advanced setup menu is provided as standard for special application requirements.
3S Technology
Automatic ramp control profiles ensure smooth start and stop performance, delivering stable acceleration and deceleration in all operating conditions.
OLED Display
Full text messages enabling fast programming and rapid fault finding with no codes and real-time value monitoring. Local display of recent logged events.
USB
for field firmware upgrades and downloading of the event logging data.
Modbus RTU
communications as standard. No need for optional communication cards.
Motor Overload Protection
Protecting the motor and soft starter in the event of an overload situation at full I²t motor overload with intelligent thermal memory retention feature. Continually monitoring overloads to ascertain the reduction in overload levels even when VMX-agility™ is in the ‘off’ state. This is combined with protection and diagnostics giving the operator peace of mind during the motor running phase.
Life Event Logging
VMX-agility™ life event logging is a unique feature that records the last 1600 events to enable fast accurate fault analysis and their resolution. Recording multiple activities including start, stop, top of ramp, faults, application parameters (time, overload level, currents, frequency) and the device information. The data is collated in StarterView programme and provides the operator with the advantage to undertake a detailed analysis of performance and equipment conditioning in an active predictive and preventative maintenance strategy to avoid unwanted breakdowns and any costly lost production time.
Loss Reduction
An integral bypass is initiated at the top of ramp and reduces losses in the soft starter.
Start Delay Feature
Intentional start delay allowing pump actuators to engage before start.
Control Circuit
A standard 24 VDC control voltage supply with an optional power module which adapts the digital input voltages to accept a 110/230 VAC signal.
Lowers Panel Production Costs
Three unit frame sizes across the voltage range of 200-600VAC with vertical or horizontal mounting to facilitate efficient panel layout and interconnections to reduce material and panel production time
Soft Stopping
Current is limited during soft stopping and gives greater control against water hammer.
Fire Mode
External input signal overriding normal controls allowing the motor to continue running in emergency situations.
Frequent Number of Starts
Optional cooling fan for frequent duty applications with up to 40 starts per hour - size 1, and from 10 to 40 starts per hour (rating dependent) - size 2.
Optional Remote Display Keypad
Plug in remote mounting unit keypad mimics the VMX-agility™ display and keypad function.
Optional Power Supply Unit Module
Unique to VMX-agility™ this module enables control voltage options in one standard product unit, no need to purchase separate soft starters for different control voltages.
Automatic Reset
Automatically resets trips in defined situations. Reduces the requirement to send a service technician to reset nuisance trips.
VMX-agility™ has been developed to exceed the exacting demands of industrial automation motor control clients.
Downloads
Brochure
User Guides
- VMX-agility - Fan Installation Guide VMX-AGY-101 to VMX-AGY-113
- VMX-agility - Fan Installation Guide VMX-AGY-201 to VMX-AGY-209
- VMX-agility - VMX-AGY-012 Remote Keypad User Guide
- VMX-agility - VMX-AGY-021 Power Supply Installation
- StartView Mlink User Manual
- VMX-agility - Quick Start Guide
- Single Phase Starting
- VMX-agility - VMX-AGY-010-N4 Nema 4/IP66 Remote Keypad User Guide
- VMX-agility - VMX-AGY-061 Terminal Shroud Installation Guide VMX-AGY-301 to VMX-AGY-305
- VMX-agility - Full User Manual
- VMX-agiity - VMX-AGY Finger Guard Installation
Specification
| Operational Voltage | 200–600 VAC |
| Rated Frequency | 50–60 Hz ± 5 Hz |
| Index Rating | Trip Class 10: 3.5-17: 90-5 (Trip Class 20 & 30) |
| Starts per Hour | Standard 5 starts/stops per hour With Optional Fan AGY-101 to 203: 40 starts/stops per hour AGY-205: 30 starts/stops per hour AGY-207: 20 starts/stops per hour AGY-209: 10 starts/stops per hour |
| Internally Bypassed | Yes |
| Screen | OLED |
| Control Supply | Standard 24 VDC With Optional Power Supply 110 to 230 VAC |
| Inputs | 2 Digital Inputs, 1 Programmable Standard 24 VDC With Optional Power Supply 110 to 230 VAC |
| Outputs | 2 Digital Outputs, 1 Programmable |
| Overload | Full I2t Motor Overload |
| Communications | Modbus RTU |
| Full Logging functionality for use with StarterView | Yes |
| IP/NEMA rating |
Size 1 IP20/NEMA Class 1 with finger guard fitted (PLS-SGY-008) Size 2 IP20/NEMA Class 1 with finger guard fitted (PLS-SGY-009) Size 3 IP00 as standard IP20/NEMA Class 1 with optional terminal cover kit (PLS-SGY-061) |
| Ambient Temperature | -20 °C to 40 °C without de-rating 60 °C with de-rating |
| Standards | CE, UL |
| Languages | English, French, German, Spanish, Portuguese, Italian |
| Warranty | 2 Years |